Climatic & weathering tests
high and low temperature test,damp heat test, thermal shock test, rapid temperature change test, fungus test, dust test, rain test, sunlight / ultraviolet aging test, high pressure test
Mechanical tests
vibration test, impact test, collision test, drop test, constant acceleration tes
AGREE tests
three tests-in-one chamber test (temperature, humidity and vibration)
Corrosion test
salt spray test, gas corrosion test, acid air test, fluid pollution test, ozone test.
1、Cold test
Cold tests and thermal tests comply with GB/T2423.1—89 and GB/T2423.22—87
Temperature range: -70℃~10℃
Dry heat tests and thermal tests comply with GB/T2423.2—89 and GB/T2423.22—87
Temperature range: 10℃~210℃
3、Damp heat test
Damp heat tests and cyclic damp heat tests comply with GB/T2423.3—93
Humidity range: 30%RH~100%RH
4、Fungus test
Fungus tests comply with GB/T2423.16—90.
Salt spray tests comply with GB/T2423.17—93
6、Low air pressure test
Low air pressure tests comply withGB/T2423.21—92, GB/T2423.25—92 and GB/T2423.26—92
Temperature range: 70℃~100℃, air pressure 0~760mmHg, humidity 20%~95%RH
7、Vibration test
Vibration tests comply with GB/T2423.10—95
Frequency range (mechanic shaker): 5~60Hz (fixed frequency 5~80Hz), max displacement 3.5mm when fully loaded
Frequency range (electrical shaker): 5~3000Hz, max displacement 25mmP-P
8、Impact test
Impact tests comply with GB/T2423.5—95
9、Collision tes
Collision tests comply with GB/T2423.6—95
10、Drop test
Drop tests comply with GB/T2423.7—95 and GB/T2423.8—95